| dc.description.abstract |
A crescente pressão sobre os recursos hídricos, associada ao aumento da demanda
por água e às limitações dos sistemas de abastecimento e esgotamento sanitário, tem
impulsionado a busca por alternativas que promovam o uso mais eficiente da água.
Nesse contexto, o reúso de águas cinzas destaca-se como uma estratégia capaz de
contribuir para a conservação dos recursos hídricos e para a redução dos impactos
ambientais associados ao consumo de água potável e à geração de efluentes. O
presente trabalho teve como objetivo avaliar o potencial de reúso não potável de
águas cinzas em uma edificação residencial, considerando sua conformidade com
diretrizes normativas e sua contribuição para a redução da pressão sobre os recursos
hídricos. A metodologia adotada consistiu na análise de dados secundários referentes
à qualidade de águas cinzas tratadas por um sistema híbrido de processos
eletroquímicos associados à filtração por membranas, complementada por medições
diretas de geração de águas cinzas em uma residência unifamiliar localizada em
Florianópolis (SC). Foram avaliados parâmetros físico-químicos e microbiológicos,
comparados a normas e diretrizes nacionais e internacionais aplicáveis ao reúso não
potável. Adicionalmente, foi realizado um balanço hídrico para estimar o potencial de
substituição de água potável em descargas sanitárias e máquina de lavar roupas, bem
como seus efeitos sobre a geração de esgoto doméstico. Também foi aplicada a
análise SWOT (Strengths, Weaknesses, Opportunities and Threats), com o objetivo
de identificar forças, fraquezas, oportunidades e ameaças associadas à implantação
do reúso de águas cinzas na edificação estudada. Os resultados indicaram que o
tratamento promoveu significativa redução da matéria orgânica e da turbidez, com
redução da DQO de 835,25 para 139,00 mg O₂/L (eficiência de aproximadamente
83,4%) e da turbidez de 175,00 para 0,18 NTU, produzindo um efluente com
características favoráveis ao reúso. Entretanto, alguns parâmetros ainda
apresentaram restrições quanto ao atendimento integral das diretrizes normativas
avaliadas, evidenciando a necessidade de etapas complementares de tratamento
para determinadas aplicações. Em termos quantitativos, verificou-se potencial de
redução de aproximadamente 24,65% do consumo de água potável e da parcela de
esgoto associada ao abastecimento da residência. A análise SWOT evidenciou que o
reúso de águas cinzas apresenta benefícios ambientais e operacionais relevantes,
embora ainda existam desafios técnicos, econômicos e regulatórios para sua ampla
implementação. Conclui-se que o reúso de águas cinzas constitui uma alternativa
promissora para a promoção da sustentabilidade hídrica em edificações residenciais,
contribuindo para o uso racional da água e para a redução da pressão sobre os
sistemas de abastecimento e disposição de efluentes. |
pt_BR |
| dc.description.abstract |
The increasing pressure on water resources, associated with rising water demand and
the limitations of water supply and wastewater management systems, has driven the
search for alternatives that promote more efficient water use. In this context, greywater
reuse stands out as a strategy capable of contributing to water resource conservation
and reducing the environmental impacts associated with potable water consumption
and wastewater generation. This study aimed to evaluate the potential for non-potable
greywater reuse in a residential building, considering its compliance with regulatory
guidelines and its contribution to reducing pressure on water resources. The adopted
methodology consisted of analyzing secondary data related to the quality of greywater
treated by a hybrid system combining electrochemical processes and membrane
filtration, complemented by direct measurements of greywater generation in a singlefamily residence located in Florianópolis, Santa Catarina, Brazil. Physicochemical and
microbiological parameters were evaluated and compared with national and
international standards and guidelines applicable to non-potable water reuse.
Additionally, a water balance assessment was conducted to estimate the potential for
replacing potable water in toilet flushing and washing machine use, as well as the
effects on domestic wastewater generation. A SWOT (Strengths, Weaknesses,
Opportunities and Threats) analysis was also applied to identify the strengths,
weaknesses, opportunities, and threats associated with implementing greywater reuse
in the studied building. The results indicated that the treatment system promoted
significant reductions in organic matter and turbidity, with COD decreasing from 835.25
to 139.00 mg O₂/L (approximately 83.4% removal efficiency) and turbidity decreasing
from 175.00 to 0.18 NTU, producing an effluent with characteristics favorable for reuse.
However, some parameters still showed limitations regarding full compliance with the
evaluated regulatory guidelines, highlighting the need for complementary treatment
steps for certain applications. From a quantitative perspective, a potential reduction of
approximately 24.65% in potable water consumption and in the portion of wastewater
associated with the household water supply was observed. The SWOT analysis
demonstrated that greywater reuse offers relevant environmental and operational
benefits, although technical, economic, and regulatory challenges still exist for its
widespread implementation. It was concluded that greywater reuse represents a
promising alternative for promoting water sustainability in residential buildings,
contributing to rational water use and reducing pressure on water supply and
wastewater disposal systems. |
pt_BR |
| dc.format.extent |
73 f. |
pt_BR |
| dc.language.iso |
por |
pt_BR |
| dc.publisher |
Florianópolis, SC. |
pt_BR |
| dc.rights |
Open Access. |
en |
| dc.subject |
Fontes alternativas de água |
pt_BR |
| dc.subject |
Uso racional da água |
pt_BR |
| dc.subject |
Tratamento de águas cinzas |
pt_BR |
| dc.subject |
Alternative water sources |
pt_BR |
| dc.subject |
Efficient water use |
pt_BR |
| dc.subject |
Greywater treatment |
pt_BR |
| dc.title |
Potencial de reúso não potável de águas cinzas em edificações urbanas: conformidade normativa e contribuições para sustentabilidade hídrica |
pt_BR |
| dc.type |
TCCgrad |
pt_BR |
| dc.contributor.advisor-co |
Anjos, Luísa Angelo dos |
|