| dc.description.abstract |
A ocupação crescente de áreas com restrições geotécnicas tem ampliado a
necessidade de soluções de contenção capazes de garantir a estabilidade de
escavações e limitar deformações no entorno. Nesse contexto, apresenta-se neste
trabalho a avaliação do comportamento tensão-deformação de uma cortina de estacas
justapostas em solo residual de gnaisse, considerando a influência da estruturação do
solo e do uso de tirantes. O estudo foi desenvolvido a partir de um empreendimento
localizado em São Bento do Sul, Santa Catarina, no qual foram realizadas a
caracterização geológica, geomorfológica e geotécnica da área, ensaios laboratoriais
em amostras indeformadas e remoldadas, o dimensionamento preliminar da
contenção e a modelagem numérica bidimensional por meio do Método dos
Elementos Finitos, utilizando o software RS2. As análises foram conduzidas em
cenários com e sem tirantes, empregando parâmetros obtidos em amostras
indeformadas e remoldadas, totalizando quatro condições de análise, de modo a
comparar o desempenho da contenção sob diferentes condições de resistência e
rigidez do maciço. Os resultados indicaram que a estruturação natural do solo residual
exerce influência significativa no comportamento da contenção, proporcionando
menores deslocamentos e respostas mais favoráveis quando comparada à condição
remoldada. Observou-se, ainda, que a utilização de tirantes contribuiu para reduzir as
deformações da estrutura e melhorar o controle dos deslocamentos do terreno
adjacente, evidenciando a relevância desse recurso no desenvolvimento do projeto.
Entre as condições analisadas, a cortina atirantada com parâmetros obtidos em
amostras indeformadas apresentou o desempenho mais satisfatório, demonstrando a
importância da adequada caracterização geotécnica e da consideração da estrutura
natural do solo no projeto de contenções em solos residuais. |
pt_BR |
| dc.description.abstract |
The increasing occupation of areas with geotechnical constraints has intensified the
need for retaining structures capable of ensuring excavation stability and limiting
ground deformations. In this context, this study evaluates the stress–strain behavior of
a contiguous pile wall constructed in gneiss residual soil, considering the influence of
soil structure and the use of ground anchors. The study was based on a construction
project located in São Bento do Sul, Santa Catarina, Brazil, and involved the
geological, geomorphological, and geotechnical characterization of the site, laboratory
triaxial tests on undisturbed and remolded soil samples, preliminary design of the
retaining structure, and two-dimensional numerical modeling using the Finite Element
Method with the RS2 software. The analyses were performed for anchored and
unanchored retaining systems, employing parameters obtained from both undisturbed
and remolded samples, resulting in four analysis scenarios to compare the structural
performance under different soil strength and stiffness conditions. The results showed
that the natural structure of the residual soil significantly influences the behavior of the
retaining system, leading to smaller displacements and improved performance
compared with the remolded condition. Furthermore, the use of ground anchors
reduced structural deformations and improved the control of ground movements,
highlighting their importance in the design of retaining structures. Among the analyzed
scenarios, the anchored pile wall modeled with parameters obtained from undisturbed
samples presented the most satisfactory performance, demonstrating the importance
of proper geotechnical characterization and consideration of the natural soil structure
in the design of retaining systems in residual soils. |
pt_BR |
| dc.format.extent |
124 f. |
pt_BR |
| dc.language.iso |
por |
pt_BR |
| dc.publisher |
Joinville, SC. |
pt_BR |
| dc.rights |
Open Access. |
en |
| dc.subject |
modelagem geomecânica; ensaio triaxial; estruturação do solo; contenção atirantada; deformações. |
pt_BR |
| dc.subject |
geomechanical modeling; triaxial test; soil structure; anchored retaining wall; deformations. |
pt_BR |
| dc.title |
Projeto geotécnico de cortinas de estacas justapostas em solo residual de gnaisse |
pt_BR |
| dc.type |
TCCgrad |
pt_BR |