Retrieval analysis em mega próteses de joelho: estudo preliminar
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina. |
pt_BR |
dc.contributor.advisor |
Roesler, Carlos Rodrigo de Mello |
|
dc.contributor.author |
Gomes, Guilherme Augusto Paquelin |
|
dc.date.accessioned |
2025-07-21T13:14:58Z |
|
dc.date.available |
2025-07-21T13:14:58Z |
|
dc.date.issued |
2025-04-01 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/266799 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina, Centro Tecnológico, Engenharia de Materiais. |
pt_BR |
dc.description.abstract |
A artroplastia de joelho é um procedimento cirúrgico amplamente utilizado para restaurar a
funcionalidade da articulação e aliviar a dor em pacientes com doenças degenerativas ou
condições oncológicas que resultam em perda óssea significativa. Em casos mais complexos,
como em pacientes oncológicos, a utilização de megapróteses se torna necessária. No entanto,
falhas mecânicas e biológicas nesses implantes podem levar a cirurgias de revisão. Neste
contexto, as técnicas de retrieval analysis surgem ferramentas essenciais para entender os
mecanismos de falha e aprimorar os dispositivos implantáveis. O presente estudo tem como
objetivo avaliar a severidade dos mecanismos de danos presentes em mega próteses de joelho
explantadas – como fretting-corrosion e desgaste – com ênfase nas interfaces de conexão
modular. Foram analisadas três (3) megapróteses de joelho explantadas, provenientes do
Instituto Nacional de Traumatologia e Ortopedia (INTO) e recebidas pelo Centro Nacional de
Análise de Explantes (CNAEx). A metodologia aplicada envolveu procedimentos de registro
e análise macroscópica, seguindo normas técnicas internacionais como ASTM F561-19 e ISO
12891. Os resultados evidenciaram diferentes padrões de degradação nas interfaces de
conexão, confirmando a ocorrência de danos por fretting-corrosion para todas as
mega próteses analisadas. |
pt_BR |
dc.description.abstract |
Knee arthroplasty is a widely used surgical procedure to restore joint functionality and relieve
pain in patients with degenerative diseases or oncological conditions that result in significant
bone loss. In more complex cases, such as in oncological patients, the use of megaprostheses
becomes necessary. However, mechanical and biological failures in these implants may lead
to revision surgeries. In this context, retrieval analysis techniques emerge as essential tools for
understanding failure mechanisms and improving implantable devices. This study aims to
assess the severity of damage mechanisms present in explanted knee megaprostheses—such
as fretting-corrosion and wear—with an emphasis on modular connection interfaces. Three
(3) explanted knee megaprostheses were analyzed, originating from the National Institute of
Traumatology and Orthopedics (INTO) and received by the National Center for Explant
Analysis (CNAEx). The methodology applied involved documentation and macroscopic
analysis procedures, following international technical standards such as ASTM F561-19 and
ISO 12891. The results revealed different degradation patterns in the connection interfaces,
confirming the presence of fretting-corrosion damage in all analyzed megaprostheses. |
pt_BR |
dc.format.extent |
101 f. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access. |
en |
dc.subject |
Artroplastia |
pt_BR |
dc.subject |
Retrieval analysis |
pt_BR |
dc.subject |
Interface de acoplamento modular |
pt_BR |
dc.subject |
Avaliação de danos |
pt_BR |
dc.subject |
Fretting-corrosion |
pt_BR |
dc.title |
Retrieval analysis em mega próteses de joelho: estudo preliminar |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
dc.contributor.advisor-co |
Cubillos, Patricia Ortega |
|
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar