Caracterização físico-química e biológica de barreira de PLGA

DSpace Repository

A- A A+

Caracterização físico-química e biológica de barreira de PLGA

Show simple item record

dc.contributor Universidade Federal de Santa Catarina. pt_BR
dc.contributor.advisor Benfatti, César Augusto Magalhães
dc.contributor.author Silva, Francine Camila da
dc.date.accessioned 2025-07-07T13:47:42Z
dc.date.available 2025-07-07T13:47:42Z
dc.date.issued 2025-06-04
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/265978
dc.description TCC (graduação) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Odontologia. pt_BR
dc.description.abstract Objetivo: avaliar e descrever as propriedades físico-químicas e biológicas de uma barreira de PLGA (BioPLAX®; NOWAD/Florianópolis SC), atualmente comercializada para aplicação em procedimentos de regeneração tecidual guiada (RTG) e regeneração óssea guiada (ROG). Materiais e Métodos: foram realizados testes de caracterização química para quantificação dos compostos potencialmente presentes; ensaio de estabilidade contendo avaliação de esterilização, envelhecimento acelerado e resistência à embalagem; análise de estrutura e morfologia com microscopia eletrônica de varredura e testes de avaliação biológica, incluindo citotoxicidade in vitro, reatividade intracutânea, toxicidade sistêmica aguda e teste de pirogênio in vivo. Resultados: a caracterização química indicou níveis aceitáveis de compostos orgânicos voláteis, semi-voláteis e não voláteis, e os demais elementos quantificados, como metáis e minerais e a determinação de ânios, apresentaram valores abaixo do limite de quantificação. No ensaio de estabilidade, a barreira manteve suas características físico-químicas e biológicas, vedação íntegra e esterilidade, com validade estimada de cinco anos. A análise de estrutura e morfologia confirmou a composição química da barreira BioPLAX®, com uma formulação de 64% (m/m) de carbono e 36% (m/m) de oxigênio. Os testes biológicos apresentaram resultados dentro dos critérios de aceitabilidade, considerando a amostra não citotóxica, com índice de reatividade intracutânea inferior a 1,0 e ausência de reações de eritema e edema, ausência de sinais de toxicidade sistêmica aguda e ausência de aumento de temperatura igual ou superior a 0,5oC no teste de pirogênio in vivo. Conclusão: a barreira apresenta características favoráveis para sua aplicação, especialmente em RTG e ROG, demonstrando biocompatibilidade, estabilidade durante o armazenamento e taxa de degradação controlada, reforçando a sua segurança e viabilidade para uso clínico. Palavras-chave: Barreira 1; PLGA 2; Regeneração tecidual guiada 3; RTG 4; Regeneração óssea guiada 5; ROG 6. pt_BR
dc.description.abstract Objective: To evaluate and describe the physicochemical and biological properties of the PLGA barrier (BioPLAX®; NOWAD/Florianópolis SC), currently marketed for use in guided tissue regeneration (GTR) and guided bone regeneration (GBR) procedures. Materials and methods: Chemical characterization tests were conducted to quantify potentially present compounds; a stability study was performed, including sterilization assessment, accelerated aging, and packaging integrity; structural and morphological analysis was carried out using scanning electron microscopy; and biological evaluation tests were conducted, including in vitro cytotoxicity, intracutaneous reactivity, acute systemic toxicity, and in vivo pyrogenicity testing. Results: Chemical characterization indicated acceptable levels of volatile, semi-volatile, and non-volatile organic compounds. Other quantified elements, such as metals, minerals, and anion determination, showed values below the limit of quantification. In the stability assay, the barrier maintained its physicochemical and biological properties, including intact sealing and sterility, with an estimated shelf life of five years. Structural and morphological analysis confirmed the chemical composition of the BioPLAX® barrier, with a formulation consisting of 64% (w/w) carbon and 36% (w/w) oxygen. Biological tests demonstrated compliance with acceptance criteria, with the sample considered non-cytotoxic, showing an intracutaneous reactivity index below 1.0, no signs of erythema or edema, absence of acute systemic toxicity, and no temperature increase equal to or greater than 0.5 °C in the in vivo pyrogenicity test. Conclusion: The barrier exhibits favorable characteristics for clinical use, particularly in GTR and GBR procedures, demonstrating biocompatibility, atorage stability, controlled degradation rate, reinforcing its safety and viability for clinical application. Keywords: Barrier 1; PLGA 2; Guided tissue regeneration 3; GTR 4; Guided bone regeneration 5; GBR 6. pt_BR
dc.format.extent 51 pt_BR
dc.language.iso por pt_BR
dc.publisher Florianópolis, SC. pt_BR
dc.rights Open Access. en
dc.subject PLGA pt_BR
dc.subject Regeneração Óssea Guiada pt_BR
dc.subject Barreira pt_BR
dc.subject Regeneração Tecidual Guiada pt_BR
dc.title Caracterização físico-química e biológica de barreira de PLGA pt_BR
dc.type TCCgrad pt_BR
dc.contributor.advisor-co Magini, Ricardo de Souza


Files in this item

Files Size Format View Description
TCC-graduação e ... ca de barreira de PLGA.pdf 1.043Mb PDF View/Open TCC
Pedido de embargo.pdf 267.9Kb PDF View/Open TCC

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar