dc.contributor.author |
Medeiros, Ayana Dantas de |
|
dc.contributor.author |
Fernandes, Guilherme de Sousa |
|
dc.contributor.author |
Santana, Rhaiana Bandeira |
|
dc.contributor.author |
Tavares, Thiago Augusto |
|
dc.contributor.author |
Amorim, Cláudia Naves David |
|
dc.date.accessioned |
2023-03-01T18:29:48Z |
|
dc.date.available |
2023-03-01T18:29:48Z |
|
dc.date.issued |
2019-05-08 |
|
dc.identifier.issn |
2596-237X |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/244760 |
|
dc.description.abstract |
Esse estudo investiga a experiência no ambiente construído quanto a estratégias de ventilação natural,
incluindo ventilação cruzada e resfriamento noturno de massa térmica. Partindo das análises
realizadas através da disciplina de Projeto Ambiental Integrado da Pós-Graduação da Faculdade de
Arquitetura da Universidade de Brasília (PPG FAU-UnB) foi proposto o retrofit em um edifício
institucional localizado no Campus da Universidade de Brasília, com o intuito de transformá-lo em
um edifício de Balanço Energético Nulo (Net-ZEB). O objetivo do artigo é apresentar as soluções de
ventilação, em especial à ventilação de massa térmica noturna, para o contexto climático de Brasília-
DF. Como método, foi levantado bibliografia específica, realizada análise bioclimática, cálculos
matemáticos manuais e o estudo de caso de retrofit em um edifício não residencial no Campus Darcy
Ribeiro. Como resultado, foi verificada a viabilidade de se utilizar o resfriamento noturno como
estratégia passiva para ventilação passiva, tendo sido entendido que é possível alcançar dados
satisfatórios que justificam seu uso no contexto climático de Brasília. |
pt_BR |
dc.description.abstract |
This is an example of research into the experience in the environment built on a natural ventilation
strategy, including cross-ventilation and night-time thermal mass cooling. Post-graduation in
Computer Engineering at the University of Brasília (PPG FAU-UnB) was implemented in an
institutional environment located on the campus of the University of Brasilia, with the purpose of
transformation. it in a building of Zero Energy Building (Net-ZEB). The article is presented as
ventilation solutions, especially for the night dynamics, for the climatic context of Brasília-DF. As a
method, a bibliographic survey of meaning, a bioclimatic analysis, mathematical and manual
calculations and the case study ofretrofit in a non -residential building in the Darcy Ribeiro Campus
were used. As a result, the feasibility of using night-time cooling as a passive strategy for passive
ventilation was analyzed, and the task of obtaining satisfactory data justifying its use in the climatic
context of Brasilia was analyzed. |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Grupo de Pesquisa Virtuhab/ UFSC |
pt_BR |
dc.subject |
Ventilação noturna; |
pt_BR |
dc.subject |
Resfriamento da massa térmica; |
pt_BR |
dc.subject |
Ventilação natural; |
pt_BR |
dc.subject |
Ventilação cruzada; Retrofit. |
pt_BR |
dc.subject |
Night ventilation; Thermal mass cooling, Natural ventilation, Cross ventilation, Retrofitting. |
pt_BR |
dc.title |
Ventilação cruzada e noturna como estratégia de resfriamento passivo em edifício institucional no contexto climático de Brasília/DF |
pt_BR |
dc.title.alternative |
Cross-ventilation and night ventilation as a passive cooling strategy in institutional building in the climatic context of Brasília/DF |
pt_BR |
dc.type |
Article |
pt_BR |