dc.description.abstract |
A energia solar é uma alternativa para diversificar a matriz elétrica do Brasil, devido ao
potencial solar do país, pela confiabilidade e maturidade que a tecnologia fotovoltaica
apresenta atualmente, além de ser uma fonte de energia economicamente competitiva.
Com a Resolução Normativa (REN) nº 482 da Agência Nacional de Energia Elétrica
(ANEEL) a geração distribuída passou a ser regulamentada no país, assim, ocorreu um
aumento significativo no número de instalações de sistemas fotovoltaicos conectados à
rede. Com esse aumento, é preciso conhecer os componentes desses sistemas e suas
funcionalidades a fim de garantir o crescimento da tecnologia e a qualidade da energia
elétrica. Em um sistema fotovoltaico conectado à rede (SFCR) tem-se o inversor, que é
responsável por fornecer energia elétrica em corrente alternada (c.a.) através de uma fonte
de energia elétrica em corrente contínua (c.c.) O fator de dimensionamento do inversor
(FDI) é definido pela razão entre a potência do inversor e a potência do gerador
fotovoltaico. Como o inversor é um equipamento eletrônico, é inevitável que durante a
sua operação o mesmo aqueça, entretanto o aquecimento excessivo deve ser evitado, pois
pode comprometer a vida útil do equipamento. Desta forma, este trabalho visa analisar a
influência da temperatura operacional de inversor no desempenho energético de SFCRs
com diferentes FDI. Analisou-se quatro SFCRs, sendo dois deles com inversores com
potência igual a 3 kW e outros dois com potência de inversor de 5 kW. Comparou-se os
dados de temperaturas reais medidas nos inversores com os dados obtidos por meio de
simulação e modelagem matemática. A temperatura real dos inversores foi medida por
meio de um sensor instalado no dissipador do inversor, enquanto, que a temperatura
simulada foi determinada utilizando os dados obtidos a partir de modelagem e simulação
dos sistemas fotovoltaicos por meio do software SAM e o modelo matemático que
descreve o perfil da temperatura operacional de inversores. Com objetivo de comparar os
SFCRs, considerou-se também os índices de mérito de produtividade e fator de
capacidade. Analisando os sistemas com mesma potência de inversor, conclui-se que os
sistemas com maiores FDI apresentaram as menores temperaturas de inversor, tanto para
as temperaturas reais quanto para as temperaturas simuladas e modeladas de inversor. |
pt_BR |
dc.description.abstract |
Solar energy is an alternative to diversify Brazil's electricity matrix, due to the country's
solar potential, the reliability and maturity that photovoltaic technology currently
presents, besides being an economically competitive energy source. With ANEEL’s REN
nº 482, distributed generation began to be regulated in the country, thus, there was a
significant increase in the number of photovoltaic system installations connected to the
network. With this increase, it is necessary to know the components of these systems and
their functionalities in order to ensure the growth of technology and the quality of
electrical energy. In an grid connected photovoltaic system (GCPS) there is the inverter,
which is responsible for supplying electrical power in a.c. through an electrical power
source in d.c. The design factor of the inverter is defined by the ratio between the inverter
power and the photovoltaic generator power. As the inverter is an electronic equipment,
it is inevitable that during its operation the same heat, however the excessive heating
should be avoided, because it can compromise the life of the equipment. Thus, this work
aims to analyze the influence of the inverter operating temperature on the energy
performance of GCPS with different inverter sizing fator (ISF). Four GCPS were
analyzed, two with inverters with power equal to 3 kW and the other two with inverter
power of 5 kW. The actual temperature data measured in the inverters were compared
with the data obtained through simulation and mathematical modeling. The actual
temperature of the inverters was measured by means of a sensor installed in the inverter
sink, while the simulated temperature was determined using the data obtained from
modeling and simulation of photovoltaic systems through the SAM software and the
mathematical model that describes the operational temperature profile of inverters. In
order to compare the GCPS, the productivity merit indices and capacity factor were also
considered. Analyzing the systems with the same inverter power, it was concluded that
the systems with higher ISF presented the lowest inverter temperatures, both for the real
temperatures and for the simulated and modeled temperatures of inverter. |
pt_BR |
dc.format.extent |
68 |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Araranguá, SC |
pt_BR |
dc.rights |
Open Access |
en |
dc.subject |
Sistemas Fotovoltaicos Conectados à Rede |
pt_BR |
dc.subject |
Temperatura de Inversor |
pt_BR |
dc.subject |
Fator de Dimensionamento de Inversor |
pt_BR |
dc.title |
Análise e influência da distribuição de temperatura de inversor no desempenho energético de sistemas fotovoltaicos de geração distribuída com distintos fatores de dimensionamento |