Análise pelo método dos elementos finitos de um dispositivo para estabilização de implantes em áreas de pneumatização do seio maxilar

DSpace Repository

A- A A+

Análise pelo método dos elementos finitos de um dispositivo para estabilização de implantes em áreas de pneumatização do seio maxilar

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Magini, Ricardo de Souza pt_BR
dc.contributor.author Siqueira, Aline Franco pt_BR
dc.date.accessioned 2012-10-22T21:48:30Z
dc.date.available 2012-10-22T21:48:30Z
dc.date.issued 2006
dc.date.submitted 2006 pt_BR
dc.identifier.other 233953 pt_BR
dc.identifier.uri http://repositorio.ufsc.br/xmlui/handle/123456789/89489
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. pt_BR
dc.description.abstract A instalação de implantes na região posterior da maxila é um desafio frente aos padrões de reabsorção pós-exodontia, pneumatização do seio maxilar e também pela qualidade do tecido ósseo remanescente. Este estudo analisou a distribuição de tensões, através do método dos elementos finitos, no tecido ósseo adjacente a um implante instalado em uma maxila posterior edêntula submetida a diferentes tratamentos. A maior concentração de tensões foi no osso cortical tanto da crista óssea quanto do assoalho do seio maxilar. O dispositivo de retenção proposto apresentou uma melhor distribuição de tensões quando comparado a ausência de tratamento, porém, as situações com enxerto ósseo mostraram-se mais favoráveis que as demais. In the posterior maxilla, implant placement is frequently complicated by unfavorable postextraction resorptive patterns, pneumatization of the maxillary sinus and the often poor quality of the remaining alveolar bone. Many techniques have been developed and tested to reduce the size and alter the anatomy of the sinus to augment the quantity of bone available for an adequate number of prosthetically well-placed implants of a satisfactory length. This in vitro study investigated the stress distribution in the bone surrounding an implant placed in a posterior edentulous maxilla. Material and Methods: 4 3D-Finite Element models of a maxillary posterior section were used to simulate different clinical scenarios: 1-no treatment, 2- a retention device, 3-bone grafts and 4-sufficient residual bone for implant placement. Axial and oblique loads of 300 N were considered and the stresses developed in the supporting structures were analyzed. Results: The von Mises stress distribution showed a high stress concentration in both cortical bone (maxillary bottom and crestal bone). The stress distribution in proposed device was better than the model with the absence of treatment and the bone grafts showed a more suitable stresses distribution than the others models. Conclusion: These findings suggest that this device could be a new clinical approach for the posterior atrophic edentulous maxilla if the in vivo studies validated the present results. pt_BR
dc.format.extent 101 f.| il., grafs., tabs. pt_BR
dc.language.iso por pt_BR
dc.publisher Florianópolis, SC pt_BR
dc.subject.classification Odontologia pt_BR
dc.subject.classification Implantes dentários pt_BR
dc.subject.classification Maxila pt_BR
dc.subject.classification Seio maxilar pt_BR
dc.subject.classification Ossos - pt_BR
dc.subject.classification Regeneração pt_BR
dc.title Análise pelo método dos elementos finitos de um dispositivo para estabilização de implantes em áreas de pneumatização do seio maxilar pt_BR
dc.type Dissertação (Mestrado) pt_BR


Files in this item

Files Size Format View
233953.pdf 904.3Kb PDF Thumbnail

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics

Compartilhar