dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Pizzolatti, Bruno Segalla |
|
dc.contributor.author |
Dalri, Lucas da Silveira |
|
dc.date.accessioned |
2020-12-14T12:15:23Z |
|
dc.date.available |
2020-12-14T12:15:23Z |
|
dc.date.issued |
2020-12-07 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/218372 |
|
dc.description |
TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Sanitária e Ambiental. |
pt_BR |
dc.description.abstract |
Atualmente, uma eficiente gestão de perdas de água é o principal desafio das prestadoras de
serviços de água no Brasil. Os principais indicadores do Sistema Nacional de Informações
sobre Saneamento - SNIS para perdas de água apontam que a evolução nos últimos anos tem
sido lenta, com índices de perdas na distribuição próximos dos 40% no país. O objetivo deste
trabalho foi executar estratégias para o diagnóstico, controle e redução de perdas de água em
um Distrito de Medição de Controle - DMC do SAA de Brusque/SC, utilizando a modelagem
hidráulica como ferramenta de tomada de decisão. As metodologias do Balanço Hídrico e das
Vazões Mínimas Noturnas foram utilizadas para um diagnóstico das perdas no DMC da
Elevatória de Água Tratada da Boemia, e a partir dos seus resultados e também do
monitoramento de pressões e análise do parque de hidrômetros, foram executadas estratégias
com o intuito de mitigar as perdas na área de estudo. Em relação às Perdas Reais, através do
gerenciamento de pressões, foi observado o mau funcionamento da Válvula Redutora de
Pressão - VRP presente no DMC e o seu correto dimensionamento acarretou em uma redução
do Fator de Pesquisa em 22% e da Vazão Mínima Noturna em 25%. Foram identificados
através de varredura com haste de escuta e simulações hidráulicas, locais para execução de
geofonamento. Em relação as perdas aparentes, foi realizada a compatibilização do cadastro
comercial do SAMAE de acordo com a NBR NM 212/02, o que apontou um elevado grau de
erros cadastrais e que os dados hoje utilizados não permitem uma análise confiável do parque
de hidrômetros do sistema. Uma revisão do número de economias do município pode
aumentar em R$ 540.000 o faturamento anual do SAMAE. Em relação às trocas de
hidrômetros, foram realizadas 202 trocas, sendo 196 pelo critério de troca do SAMAE e 6
através da análise do LSC e do FT. Por fim, foram indicados pontos de melhoria na operação
do SAMAE, para que a gestão de perdas de água realizada pela autarquia se torne mais
eficiente. |
pt_BR |
dc.description.abstract |
Currently, efficient water loss management is the main challenge for water supply providers
in Brazil. The main indicators on SNIS for water losses, point out that the evolution in recent
years has been slow, with distribution loss rates close to 40% in the country. The objective of
this work was to execute strategies for the diagnosis, control and reduction of water losses in a
DMA of the SAA of Brusque/SC, using hydraulic modelling as a decision-making tool. The
Water Balance and Minimum Night Flow methodologies were used to diagnose losses in the
DMA of EAT Boemia, and based on their results and also on the monitoring of pressures and
analysis of the hydrometer park, with the aim of mitigating losses in the studied area. In
relation to Real Losses, through the management of pressures, it was observed the
malfunction of the PRV present in the DMA and its correct dimensioning resulted in a
reduction of the Research Factor by 22% and in the Minimum Night Flow by 25%. Spots for
the execution of geophoning services were identfied through hydraulic simulations and
listening devices. In relation to apparent losses, SAMAE's commercial register was made
compatible according to NBR NM 212/02, which pointed out a high degree errors and that the
data used today does not allow a reliable analysis of the park's water meters system. A review
of the number of registered customers may increase SAMAE's annual revenue by R$ 540,000.
In relation to water meter exchanges, 202 were made, 196 of which were based on the
SAMAE exchange criteria and 6 through the LSC and FT analysis. Finally, points of
improvement for the SAMAE operation were indicated, so that the water loss reduction policy
becomes more efficient. |
pt_BR |
dc.format.extent |
178 f. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC. |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Controle de Perdas de Água |
pt_BR |
dc.subject |
Modelagem Hidráulica |
pt_BR |
dc.subject |
Sistemas de Abastecimento de Água |
pt_BR |
dc.subject |
Balanço Hídrico |
pt_BR |
dc.subject |
Vazão Mínima Noturna |
pt_BR |
dc.subject |
Water Loss Control |
pt_BR |
dc.subject |
Hydraulic Modeling |
pt_BR |
dc.subject |
Water Supply System |
pt_BR |
dc.subject |
Water Balance |
pt_BR |
dc.subject |
Minimum Night Flow |
pt_BR |
dc.title |
Diagnóstico e execução de estratégias de controle e redução de perdas de água com uso da modelagem hidráulica: estudo de caso em um dmc no município de Brusque/sc. |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
dc.contributor.advisor-co |
Fernandes, Eduardo Pauly |
|