dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2015 |
pt_BR |
dc.description.abstract |
A condensação convectiva no interior de oito microcanais, com diâmetro hidráulico de 1,24 mm, contidos em um perfil comercial do tipo MPE (Multi Port Extruded) de alumínio foi estudada nesta dissertação. O fluido de trabalho empregado foi o R134a, e o modo de resfriamento foi obtido por meio de um sumidouro de calor constituído de um fluxo forçado de mistura de água e etileno glicol a temperaturas entre -6 e -12ºC. Um aspecto inovador neste aparato experimental foi a medição do fluxo de calor utilizando transdutores de fluxo de calor. Foram realizados testes monofásicos para a queda de pressão e transferência de calor a fim de validar o aparato experimental mediante a comparação dos resultados com os calculados com as correlações da literatura. Testes em condensação foram feitos com fluxos mássicos variando entre 154 e 308 kg/m²s, títulos variando entre 0,97 e 1, fluxos de calor entre 8,1 e 12,2 kW/m² e pressões entre 6,8 e 9,6 bar. De acordo com o mapa de padrões de Coleman e Garimella os pontos de operação testados indicaram os padrões anular-misto e anular. Os resultados experimentais comparados às correlações de Cavallini (2006) forneceram os menores desvios médios absolutos: 16,7% para a queda de pressão e 77,5% para o coeficiente de transferência de calor. <br> |
pt_BR |
dc.description.abstract |
Abstract : The convective condensation inside eight microchannels, with hydraulic diameter equal to 1,24 mm, contained in a profile type MPE (Multi Port Extruded) of aluminum was studied in this work. The working fluid used is R134a, and its cooling was made by a heat sink constituted by a water ethylenglicol mixture forced flow at temperatures between -6 and -12ºC. An innovative aspect in this experimental apparatus was the measurement of the heat flux using heat flux transducers. Single-phase tests for pressure drop and heat transfer were made in order to validate the experimental apparatus comparimg the data to the results from the classic literature correlations for single-phase flow. Tests on condensation were made with mass flows ranging from 154 to 308 kg / m²s , quality ranging from 0,97 to 1, heat flows between 8,1 to 12,2 kW / m² and pressures between 6,8 to 9,6 bar. Acording to the flow pattern map of Coleman and Garimella, the data points tested show annular-mist and annular flow patterns. The experimental results comparing with the correlations of Cavallini (2006) provided the least average deviations: 16.7% for the pressure drop and 77.5% for the heat transfer coeficient. |
en |
dc.format.extent |
169 p.| il., grafs., tabs. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.subject.classification |
Engenharia mecânica |
pt_BR |
dc.subject.classification |
Capacitadores |
pt_BR |
dc.subject.classification |
Refrigeração |
pt_BR |
dc.subject.classification |
Escoamento multifásico |
pt_BR |
dc.subject.classification |
Condensação |
pt_BR |
dc.title |
Condensação convectiva no interior de um perfil de alumínio tipo MPE contendo oito microcanais paralelos |
pt_BR |
dc.type |
Dissertação (Mestrado) |
pt_BR |
dc.contributor.advisor-co |
Guths, Saulo |
pt_BR |