Wetlands construídos empregados no tratamento descentralizado de águas cinzas residencial e de escritório

DSpace Repository

A- A A+

Wetlands construídos empregados no tratamento descentralizado de águas cinzas residencial e de escritório

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Sezerino, Pablo Heleno pt_BR
dc.contributor.author Monteiro, Victória Regina Celso pt_BR
dc.date.accessioned 2014-08-06T18:07:36Z
dc.date.available 2014-08-06T18:07:36Z
dc.date.issued 2014 pt_BR
dc.identifier.other 327447 pt_BR
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/123366
dc.description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014. pt_BR
dc.description.abstract Dentre as tecnologias de saneamento descentralizado mais utilizadas para o tratamento de águas cinzas (AC), destacam-se os wetlands construídos. Este trabalho tem como objetivo geral avaliar o comportamento de wetlands construídos de fluxo horizontal (WH) e vertical (WV) empregados no tratamento de AC residencial e de escritório, respectivamente. Para tanto, foi realizada caracterização quali-quantitativa das AC geradas, por meio de amostragens simples e compostas, bem como por meio de medição de vazão in loco. Foram avaliadas, ainda, as eficiências alcançadas pelos WH (8 m² de área superficial) e WV (9,2 m² de área superficial) no tratamento das AC, bem como suas implicações de uso e viabilidade dos efluentes tratados à um potencial reúso. Não se observou diferença estatística entre os resultados das amostragens simples e compostas para nenhum parâmetro na AC da residência, contudo, para a AC do escritório, observou-se diferença no pH e N-NH4+. Com relação à caracterização quantitativa obteve-se 102,3 L/d (34 L/pessoa.d) para residência e 50 L/d (2,14 L/pessoa.d) para o escritório. Destaca-se que a AC da residência apresentou concentrações de DQO e de P-PO43- elevadas, com médias de 1025 mg/L e de 63 mg/L, respectivamente. Já para a AC do escritório, destaca-se uma concentração de DQO de 100 mg/L e de N-NH4+ de 20 mg/L. O WH atingiu elevadas eficiências de remoção de DQO (83%, considerando uma carga aplicada de 12,3 gDQO/m2.d), P-PO43- (73%) e SS (94%). No WV, também obtiveram-se expressivas remoções de DQO (88%, com carga de 0,5 gDQO/m².d), SS (93%) e N-NH4+ (97%), sendo, inclusive observada a nitrificação (7,5 mgNO3-/L no efluente tratado). A quantidade de efluente produzido em ambos os sistemas não atendeu por completo as potenciais demandas para um reúso nos empreendimentos. As AC tratadas não atenderam os limites estabelecidos na literatura brasileira vinculadas ao reúso em relação aos parâmetros turbidez, coliformes fecais, DBO, fósforo total, SST e SDT, contudo, podem ser lançados no ambiente por meio de infiltração no solo.<br> pt_BR
dc.description.abstract Abstract : Among the most commonly used decentralized sanitation technologies for greywater (GW) treatment, highlights the constructed wetlands. The general aim of this work is to evaluate the behavior of constructed wetlands as horizontal flow (HW) and vertical flow (VW) applied on residential and office GW treatment, respectively. A qualitative and quantitative characterization of the GW generated was realized, through simple and compounds samples as well as an in loco flow measurement. The efficiencies reached by HW (8 m² superficial area) and VW (9.2 m² superficial area) were evaluated too, besides the implications of use and viability of the treated effluent reuse potential. No statistic differences was observed between the results of the simple and compounds GW?s samples for any parameter in the residence, however, in the offices GW were observed differences for pH and N-NH4+. In relation to the quantitative characterization was obtained 102.3 L/d (34 L/person.d) for the residence and 50 L/d (2.14 L/person.d) for the office. The residential?s GW showed high concentrations of COD and P-PO43-, with an average of 1025 mg/L and 63 mg/L. For the office?s GW, de average concentration was 100 mgCOD/L and 20 mgN-NH4+/L. The HW has reached good efficiencies of removal for COD (83%, considering an organic loading rate of 12,3 gCOD/m2.d), P-PO43- (73%) and SS (94%). In the VW also were obtained expressive removals of COD (88%, with organic loading rate of 0.5 gDQO/m².d), SS (93%) and N-NH4+ (97%), being inclusive observed nitrification (7.5 mgNO3-/L on treated effluent). The quantity of effluent produced in both systems did not reached the total potential demands for reuse. Both treated GW effluents did not reached the limits established on brazilian literature for reuse with respect to parameters turbidity, fecal coliforms, BOD, total phosphorus, SST and SDT, however, they could be disposed in the environment by soil infiltration. en
dc.format.extent 125 p.| il., grafs., tabs. pt_BR
dc.language.iso por pt_BR
dc.subject.classification Engenharia ambiental pt_BR
dc.subject.classification Águas residuais pt_BR
dc.subject.classification Purificação pt_BR
dc.title Wetlands construídos empregados no tratamento descentralizado de águas cinzas residencial e de escritório pt_BR
dc.type Dissertação (Mestrado) pt_BR
dc.contributor.advisor-co Philippi, Luiz Sergio pt_BR


Files in this item

Files Size Format View
327447.pdf 2.603Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics

Compartilhar