<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>TCC Engenharia Aeroespacial  (Joinville)</title>
<link>https://repositorio.ufsc.br/handle/123456789/115612</link>
<description/>
<pubDate>Sat, 05 Sep 2026 17:50:29 GMT</pubDate>
<dc:date>2026-09-05T17:50:29Z</dc:date>
<image>
<title>TCC Engenharia Aeroespacial  (Joinville)</title>
<url>http://repositorio.ufsc.br:80/xmlui/bitstream/id/b40685f4-2666-4170-b637-1079276ed240/</url>
<link>https://repositorio.ufsc.br/handle/123456789/115612</link>
</image>
<item>
<title>Limites da manufatura aditiva por estereolitografia na reprodução fiel de estruturas porosas</title>
<link>https://repositorio.ufsc.br/handle/123456789/274428</link>
<description>Limites da manufatura aditiva por estereolitografia na reprodução fiel de estruturas porosas
Piretti, João Eduardo
O estudo das propriedades de transporte em meios porosos desempenha um papel es&#13;
tratégico na modelagem de reservatórios e no escoamento de fluidos subterrâneos. A &#13;
caracterização dessas estruturas complexas em escala de poro fundamenta-se tradicio&#13;
nalmente em dados tridimensionais de microtomografia computadorizada de raios X, mas &#13;
a validação desses modelos exige o confronto direto com réplicas físicas em ambiente &#13;
laboratorial. Diante dessa necessidade, este trabalho teve como objetivo geral avaliar a &#13;
fidelidade dimensional e os limites físicos de reprodutibilidade de estruturas porosas ar&#13;
tificiais e matrizes de formas geométricas manufaturadas por impressão 3D baseada em &#13;
fotopolimerização sob diferentes fatores de ampliação de escala. A metodologia desen&#13;
volvida consistiu na fabricação de corpos de prova contendo geometrias elementares em &#13;
formato de disco, quadrado e cruz, além de seções transversais baseadas em uma rocha &#13;
digital real. Para viabilizar a análise visual, aplicou-se um protocolo físico de deposição de &#13;
contraste superficial com massa de quartzo fina seguido pelo imageamento por microsco&#13;
pia óptica estereoscópica. A quantificação analítica dos desvios morfológicos foi executada &#13;
por meio de rotinas automatizadas de processamento digital de imagens com a aplicação &#13;
do algoritmo de binarização. Os resultados experimentais indicaram que o fenômeno de &#13;
cura por luz ultravioleta atua como o principal limitante tecnológico do processo por induzir &#13;
o arredondamento de cantos vivos enquanto a resina ainda líquida passa pelo processo &#13;
de cura. Essa dispersão da radiação provocou uma redução sistemática na porosidade &#13;
superficial calculada e uma perda de fidelidade dimensional que se mostrou inversamente &#13;
proporcional ao fator de ampliação. Apesar das restrições geométricas identificadas nas &#13;
menores escalas, os ensaios confirmaram a excelente repetibilidade e o controle morfo&#13;
lógico proporcionados pela tecnologia de projeção digital. Conclui-se que os modelos de &#13;
incerteza gerados nesta investigação estabelecem uma ferramenta de apoio indispensá&#13;
vel para parametrizar os erros de fabricação antes da condução de ensaios laboratoriais &#13;
dinâmicos.; The study of transport properties in porous media plays a strategic role in reservoir model-ing and subsurface fluid flow. The characterization of these complex structures at the pore scale is traditionally based on three-dimensional X-ray micro-computed tomography (micro-CT) data; however, the validation of these models requires direct comparison with physical replicas under laboratory conditions. In this context, the main objective of this study was to evaluate the dimensional fidelity and the physical reproducibility limits of artificial porous structures and geometric-pattern matrices manufactured by vat photopolymerization-based 3D printing under different geometric upscaling factors. The proposed methodology con-sisted of fabricating specimens containing elementary geometries in the form of circular, square, and cross-shaped features, as well as cross-sectional models derived from a real digital rock. To enable visual analysis, a physical surface-contrast deposition protocol us-ing fine quartz powder was applied, followed by stereoscopic optical microscopy imaging. Morphological deviations were quantitatively assessed through automated digital image processing routines employing image binarization algorithms. The experimental results in-dicated that ultraviolet light overcuring is the primary technological limitation of the process, as it promotes the rounding of sharp edges while the resin remains in the liquid phase during photopolymerization. This light scattering effect led to a systematic reduction in the calcu-lated surface porosity and a loss of dimensional fidelity that was inversely proportional to the geometric upscaling factor. Despite the geometric limitations observed at smaller scales, the experiments demonstrated excellent repeatability and morphological control provided by the digital light projection technology. It is concluded that the uncertainty models devel-oped in this investigation provide an essential tool for quantifying manufacturing errors prior to conducting dynamic laboratory experiments.
TCC (graduação) - Universidade Federal de Santa Catarina, Campus Joinville, Engenharia Aeroespacial.
</description>
<pubDate>Tue, 30 Jun 2026 00:00:00 GMT</pubDate>
<guid isPermaLink="false">https://repositorio.ufsc.br/handle/123456789/274428</guid>
<dc:date>2026-06-30T00:00:00Z</dc:date>
</item>
<item>
<title>Spray Flame Characterization of the CORIA Rouen Spray Burner (CRSB) using Optical Diagnostics</title>
<link>https://repositorio.ufsc.br/handle/123456789/274375</link>
<description>Spray Flame Characterization of the CORIA Rouen Spray Burner (CRSB) using Optical Diagnostics
Beltramin, Mateus Castanho
Este trabalho teve como objetivo desenvolver e validar uma bancada experimental para o CORIA Rouen Spray Burner (CRSB) e caracterizar a chama produzida por meio de técnicas de diagnóstico óptico. O CRSB é um queimador atmosférico equipado com um injetor simplex DANFOSS e um plenum para geração de co-escoamento de ar. Para sua operação, um sistema de injeção completo foi projetado e montado em uma placa de aço, integrando medidores de vazão, uma bomba e uma interface LabVIEW para controle dos componentes. Com o objetivo de reproduzir as condições de baixa temperatura encontradas em voo de alta altitude, um sistema de resfriamento baseado em um circulador refrigerado Julabo FP50-HE e um trocador de calor foi integrado à bancada. O sistema foi capaz de reduzir a temperatura do combustível a −20 °C na entrada do queimador; no entanto, medições próximas ao injetor indicaram que as perdas térmicas internas ao queimador são não negligenciáveis, impedindo que temperaturas subzero fossem atingidas no ponto de injeção. Para caracterizar a chama, duas técnicas de diagnóstico óptico foram aplicadas: a quimiluminescência e a Anemometria Laser Doppler (LDA). A quimiluminescência, utilizando uma câmera ICCD Teledyne PI-MAX 4 com filtro BG12, permitiu determinar a geometria e a altura de levantamento da chama para n-heptano e n-decano. Os resultados mostraram alturas de levantamento de 22,56 mm e 21,52 mm para n-heptano (pelos métodos de média simples e RMS, respectivamente) e de 23,20 mm para n-decano em ambos os métodos, indicando maior estabilidade desta chama. A LDA, utilizando um sistema DANTEC comercial, forneceu perfis de velocidade tridimensionais em seis posições axiais. Os perfis obtidos são coerentes com resultados reportados na literatura para o mesmo queimador, validando a bancada montada. As principais limitações identificadas dizem respeito à impossibilidade de atingir temperaturas de injeção subzero com a configuração atual, sendo necessária uma modificação geométrica do CRSB para permitir o resfriamento de todo o sistema de injeção.&#13;
&#13;
Abstract: This work aimed to develop and validate a test bench for the CORIA Rouen Spray Burner (CRSB) and to characterize the flame it produces using optical diagnostic techniques. The CRSB is an atmospheric burner equipped with a DANFOSS simplex fuel injector and a plenum for generating an air co-flow. To operate the burner, a complete injection system was designed and assembled on a steel plate, integrating flowmeters, a pump, and a LabVIEW interface for component control. With the objective of reproducing the low-temperature conditions encountered during high-altitude flight, a cooling system based on a Julabo FP50-HE refrigerated circulator and a heat exchanger was integrated into the setup. The system successfully brought the fuel temperature to −20 °C at the burner inlet; however, temperature measurements near the injector indicated that internal thermal losses within the burner are not negligible, preventing subzero temperatures from being achieved at the injection point. To characterize the flame, two optical diagnostic techniques were applied: chemiluminescence imaging and Laser Doppler Anemometry (LDA). Chemiluminescence imaging, using a Teledyne PI-MAX 4 ICCD camera with a BG12 bandpass filter, allowed the determination of flame geometry and lift height for n-heptane and n-decane flames. Lift heights of 22.56 mm and 21.52 mm were found for n-heptane using the simple averaging and RMS methods, respectively, while n-decane yielded 23.20 mm for both methods, indicating greater flame stability. The LDA measurements, performed with a commercial DANTEC system, provided three-dimensional velocity profiles at six axial positions. The obtained profiles are coherent with results reported in the literature for the same burner, confirming the validity of the assembled setup. The primary limitation identified is the inability to achieve subzero injection temperatures with the current configuration; a geometric modification of the CRSB would be required to allow cooling of the entire injection system.; This work aimed to develop and validate a test bench for the CORIA Rouen Spray Burner (CRSB) and to characterize the flame it produces using optical diagnostic techniques. The CRSB is an atmospheric burner equipped with a DANFOSS simplex fuel injector and a plenum for generating an air co-flow. To operate the burner, a complete injection system was designed and assembled on a steel plate, integrating flowmeters, a pump, and a LabVIEW interface for component control. With the objective of reproducing the low-temperature conditions encountered during high-altitude flight, a cooling system based on a Julabo FP50-HE refrigerated circulator and a heat exchanger was integrated into the setup. The system successfully brought the fuel temperature to −20 °C at the burner inlet; however, temperature measurements near the injector indicated that internal thermal losses within the burner are not negligible, preventing subzero temperatures from being achieved at the injection point. To characterize the flame, two optical diagnostic techniques were applied: chemiluminescence imaging and Laser Doppler Anemometry (LDA). Chemiluminescence imaging, using a Teledyne PI-MAX 4 ICCD camera with a BG12 bandpass filter, allowed the determination of flame geometry and lift height for n-heptane and n-decane flames. Lift heights of 22.56 mm and 21.52 mm were found for n-heptane using the simple averaging and RMS methods, respectively, while n-decane yielded 23.20 mm for both methods, indicating greater flame stability. The LDA measurements, performed with a commercial DANTEC system, provided three-dimensional velocity profiles at six axial positions. The obtained profiles are coherent with results reported in the literature for the same burner, confirming the validity of the assembled setup. The primary limitation identified is the inability to achieve subzero injection temperatures with the current configuration; a geometric modification of the CRSB would be required to allow cooling of the entire injection system.
TCC (graduação) - Universidade Federal de Santa Catarina, Campus Joinville, Engenharia Aeroespacial.
</description>
<pubDate>Sat, 26 Jun 0023 00:00:00 GMT</pubDate>
<guid isPermaLink="false">https://repositorio.ufsc.br/handle/123456789/274375</guid>
<dc:date>0023-06-26T00:00:00Z</dc:date>
</item>
<item>
<title>Análise crítica sobre o uso da ISO 9001 para fortalecer os controles internos visando à conformidade com a Lei Sarbanes-Oxley</title>
<link>https://repositorio.ufsc.br/handle/123456789/274374</link>
<description>Análise crítica sobre o uso da ISO 9001 para fortalecer os controles internos visando à conformidade com a Lei Sarbanes-Oxley
Amancio, Felipe Nepomuceno da Costa Ladeira
O presente trabalho apresenta uma análise crítica sobre a integração da norma&#13;
ISO 9001 como ferramenta estratégica para o fortalecimento dos controles inter-&#13;
nos, visando a conformidade com a Lei Sarbanes-Oxley (SOX). Diante do cenário&#13;
corporativo global, que exige transparência e mitigação de riscos de fraudes finan-&#13;
ceiras, a convergência entre sistemas de gestão da qualidade e exigências regula-&#13;
tórias torna-se um diferencial competitivo. O objetivo central é analisar como os&#13;
requisitos de padronização, abordagem por processos e melhoria contínua da ISO&#13;
9001 podem estruturar o ambiente de controle necessário para atender aos títulos&#13;
e seções da SOX. A pesquisa caracteriza-se como um estudo de caso de natureza&#13;
qualitativa, descritiva e exploratória. Foram analisados artigos acadêmicos, pu-&#13;
blicações em revistas e livros, em conjunto com a vivência profissional do autor,&#13;
para fundamentar o argumento de como a documentação da qualidade serve de&#13;
base para a evidência de controles internos. Os resultados indicam que a ISO&#13;
9001 provê uma infraestrutura sólida para a SOX, especialmente no que tange à&#13;
rastreabilidade de informações, à definição de responsabilidades e ao estabeleci-&#13;
mento de controles. A utilização de auditorias internas da qualidade auxilia na&#13;
identificação precoce de lacunas nos controles, reduzindo redundâncias e custos de&#13;
conformidade. Conclui-se que a adoção conjunta dessas estruturas não apenas con-&#13;
tribui com a conformidade estatutária, mas promove uma cultura organizacional&#13;
focada na integridade e na eficiência operacional, demonstrando que a qualidade&#13;
e o compliance são áreas complementares e interdependentes.; This thesis presents a critical analysis on the integration of the ISO 9001 standard&#13;
as a strategic tool for strengthening internal controls, thus achieving compliance&#13;
with the Sarbanes-Oxley Act (SOX). In the current global corporate landscape,&#13;
which demands transparency and mitigation of financial fraud risks, the conver-&#13;
gence between quality management systems and regulatory criteria becomes a&#13;
competitive advantage. The central objective is to analyze how the standardiza-&#13;
tion requirements, process approach, and continuous improvement of ISO 9001 can&#13;
structure the control environment necessary to meet the requirements of the SOX.&#13;
The research is characterized as a qualitative, descriptive, and exploratory case&#13;
study. Academic articles, journal publications, and books were analyzed, along&#13;
with the author’s professional experience, to support the argument of how qual-&#13;
ity documentation serves as a basis for evidence of internal controls. The results&#13;
indicate that ISO 9001 provides a solid infrastructure for SOX, especially regard-&#13;
ing information traceability, definition of responsibilities, and the establishment of&#13;
controls. The use of international quality audits helps in the early identification of&#13;
gaps in controls, reducing redundancies, and compliance costs. It is concluded that&#13;
the joint adoption of these frameworks not only guarantees statutory compliance&#13;
but also promotes an organizational culture focused on integrity and operational&#13;
efficiency, demonstrating that quality and compliance are complementary and in-&#13;
terdependent areas
TCC (graduação) - Universidade Federal de Santa Catarina, Campus Joinville, Engenharia Aeroespacial.
</description>
<pubDate>Wed, 10 Jun 2026 00:00:00 GMT</pubDate>
<guid isPermaLink="false">https://repositorio.ufsc.br/handle/123456789/274374</guid>
<dc:date>2026-06-10T00:00:00Z</dc:date>
</item>
<item>
<title>Monitoramento da saúde estrutural na aviação: Estudo comparativo de métodos de detecção de falha sob as perspectivas técnica, normativa e operacional</title>
<link>https://repositorio.ufsc.br/handle/123456789/274350</link>
<description>Monitoramento da saúde estrutural na aviação: Estudo comparativo de métodos de detecção de falha sob as perspectivas técnica, normativa e operacional
Furtado, Heloise vieira Sônego
Este trabalho apresenta uma análise comparativa de métodos aplicados ao monitora&#13;
mento da saúde estrutural (SHM) em estruturas aeronáuticas, com foco na detecção&#13;
de falhas de fadiga em ligas de alumínio e delaminações em materiais compósitos. O&#13;
estudo parte da identificação do problema relacionado à crescente demanda por aero&#13;
naves mais seguras, eficientes e com custos de manutençãoreduzidos, justificando-se&#13;
pela relevância do tema frente à complexidade e criticidade dos sistemas estruturais&#13;
em voo. O objetivo principal é identificar e comparar a eficácia de diferentes tecno&#13;
logias de sensores e algoritmos de processamento sob a ótica da Probabilidade de&#13;
Detecção (POD). Para tal, a metodologia fundamenta-se em uma revisão sistemá&#13;
tica da literatura e na análise de normas fundamentais como a SAE ARP6461 e a&#13;
MIL-HDBK-1823A, avaliando métodos como Ondas de Lamb, Sensores de Fibra Óp&#13;
tica (FBG), Emissão Acústica e Análise de Vibração. Os resultados demonstram que,&#13;
embora as tecnologias apresentem alta sensibilidade em ambiente laboratorial, a tran&#13;
sição para a manutenção baseada na condição (CBM) em larga escala ainda enfrenta&#13;
desafios de robustez ambiental e certificação normativa. Conclui-se que a integração&#13;
de sistemas híbridos e a quantificação estatística da confiabilidade do diagnóstico são&#13;
os pilares para a viabilidade operacional do SHM na aviação moderna.; This paper presents a comparative analysis of methods applied to Structural Health Monitoring (SHM) in aeronautical structures, focusing on the detection of fatigue damage in aluminum alloys and delamination in composite materials. The study begins by identifying the problem associated with the growing demand for safer, more efficient aircraft with reduced maintenance costs, which is justified by the relevance of the topic given the complexity and criticality of in-flight structural systems. The primary objective is to identify and compare the effectiveness of different sensor technologies and processing algorithms from the perspective of Probability of Detection (POD). To this end, the methodology is based on a systematic literature review and the analysis of key standards such as SAE ARP6461 and MIL-HDBK-1823A, evaluating methods such as Lamb Waves, Fiber Bragg Grating (FBG) sensors, Acoustic Emission, and Vibration Analysis. The results demonstrate that although these technologies exhibit high sensitivity in laboratory environments, the transition to large-scale Condition-Based Maintenance (CBM) still faces challenges regarding environmental robustness and regulatory certification. It is concluded that the integration of hybrid systems and the statistical quantification of diagnostic reliability are the fundamental pillars for the operational viability of SHM in modern aviation.
TCC (graduação) - Universidade Federal de Santa Catarina, Campus Joinville, Engenharia Aeroespacial.
</description>
<pubDate>Thu, 18 Jun 2026 00:00:00 GMT</pubDate>
<guid isPermaLink="false">https://repositorio.ufsc.br/handle/123456789/274350</guid>
<dc:date>2026-06-18T00:00:00Z</dc:date>
</item>
</channel>
</rss>
