TCC (graduação) - Universidade Federal de Santa Catarina, Campus Joinville, Engenharia Aeroespacial. |
pt_BR |
| dc.description.abstract |
Este trabalho apresenta o desenvolvimento de um plano de manutenção para um
modelo de bomba centrífuga industrial, considerando que este equipamento alimenta
um circuito fechado de água para refrigeração do forno em uma nova instalação de
indústria vidreira. O sistema de refrigeração está entre os itens de altíssima criticidade
em um processo industrial onde há fusão ininterrupta de matéria-prima em
temperaturas elevadas a cerca de 1600°C. Portanto, a manutenção aplicada aos
componentes deste sistema deve procurar garantir o pleno funcionamento do mesmo
e, dessa forma, assegurar que a produção não seja impactada por falhas de
equipamentos. Diante da necessidade de assegurar o pleno funcionamento deste
ativo, o estudo busca definir um plano de manutenção robusto, cientificamente
embasado, para melhoria no desempenho e na confiabilidade da bomba. A
metodologia adotada, baseada nos princípios de confiabilidade, inicia-se com a
análise de um vasto conjunto de dados de falha de uma população de equipamentos
semelhantes fornecidos pela base Offshore & Onshore Reliability Data (OREDA),
utilizando ferramentas quantitativas para identificar o perfil de risco, determinar o
Tempo Médio Até a Falha (MTTF) e estabelecer a priorização dos modos de falha.
Essa análise é complementada pela validação cruzada com a matriz de causas
fornecida pelo fabricante da bomba, permitindo a identificação dos mecanismos
causais das falhas mais prováveis. Como resultado, estruturou-se uma estratégia de
manutenção híbrida, dividida em duas linhas de atuação: a Manutenção Preventiva
Baseada no Tempo, para mitigar falhas críticas de vazamento, e a Manutenção
Preventiva por Condição (Preditiva), para interceptar anomalias mecânicas e de
instrumentação em seus estágios iniciais. O modelo elaborado foi submetido à
avaliação de especialistas da área, recebendo validação técnica positiva quanto à sua
adequação estrutural e viabilidade operacional. Conclui-se que o plano proposto
atende ao objetivo manter a confiabilidade do equipamento, protegendo a integridade
da planta produtiva. Por fim, evidencia-se que a implementação em ambiente
operacional real, visando o cálculo do MTTF local e futuras análises financeiras,
permanece como a etapa subsequente essencial para comprovar no ambiente real a
melhoria proposta. |
pt_BR |
| dc.description.abstract |
This work presents the development of a maintenance plan for an industrial centrifugal
pump model, considering that this equipment feeds a closed-loop water circuit for
furnace cooling in a new glass manufacturing plant. The cooling system is among the
most critical items in an industrial process where there is uninterrupted melting of raw
materials at high temperatures of approximately 1600°C. Therefore, the maintenance
applied to the components of this system must seek to ensure its full functionality and,
in this way, guarantee that production is not impacted by equipment failures. Given the
need to ensure the full functionality of this asset, the study aims to define a robust,
scientifically based maintenance plan for improving the pump's performance and
reliability. The adopted methodology, based on reliability principles, begins with the
analysis of a vast set of failure data from a population of similar equipment provided
by the Offshore & Onshore Reliability Data (OREDA) database , utilizing quantitative
tools to identify the risk profile, determine the Mean Time To Failure (MTTF), and
establish the prioritization of failure modes. This analysis is complemented by a crossvalidation with the causes matrix provided by the pump manufacturer, allowing the
identification of the casual mechanisms of the most probable failures. As a result, a
hybrid maintenance strategy was structured around two lines of action: Time-Based
Preventive Maintenance, to mitigate critical leakage failures, and Condition-Based
Preventive Maintenance (Predictive), to detect mechanical and instrumentation
anomalies at their early stages. The developed model was submitted for evaluation by
specialists in the field, receiving positive technical validation regarding its structural
suitability and operational feasibility. It is concluded that the proposed plan meets the
objective of maintaining equipment's reliability while protecting the integrity of the
production plant. Finally, it is evident that implementation in a real operational
environment, aiming to calculate the local MTTF and conduct future financial analyses,
remains the essential subsequent step to prove the proposed improvement in a realworld setting. |
pt_BR |
| dc.format.extent |
84 f. |
pt_BR |
| dc.language.iso |
por |
pt_BR |
| dc.publisher |
Joinville, SC. |
pt_BR |
| dc.rights |
Open Access. |
en |
| dc.subject |
Manutenção industrial |
pt_BR |
| dc.subject |
Confiabilidade |
pt_BR |
| dc.subject |
OREDA |
pt_BR |
| dc.title |
Desenvolvimento de plano de manutenção para uma bomba centrífuga industrial com base em dados de confiabilidade do OREDA. |