| dc.contributor |
Universidade Federal de Santa Catarina. |
pt_BR |
| dc.contributor.advisor |
Ritter, Daltro Eneas |
|
| dc.contributor.author |
Hering, Arthur Luis Xavier |
|
| dc.date.accessioned |
2026-06-16T11:55:05Z |
|
| dc.date.available |
2026-06-16T11:55:05Z |
|
| dc.date.issued |
2026-05-08 |
|
| dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/273582 |
|
| dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Odontologia. |
pt_BR |
| dc.description.abstract |
Analisa-se, por meio de revisão narrativa da literatura, os principais polímeros utilizados na fabricação de alinhadores odontológicos e suas implicações no desempenho mecânico, físico-químico e biológico desses dispositivos. Realiza-se busca bibliográfica em PubMed, PubMed Central (PMC), SciELO e LILACS, ao longo do ano de 2025, com inclusão prioritária de estudos publicados nos últimos cinco anos e admissão excepcional de trabalhos seminais para fundamentação conceitual. Organiza-se a síntese de forma temática, abordando materiais termoplásticos empregados em alinhadores, com ênfase em PETG, poliuretanos termoplásticos, copolímeros, blends e estruturas multicamadas. Discute-se que o comportamento viscoelástico dos polímeros, expresso por relaxamento de tensão e fluência, influencia a manutenção de forças ao longo do tempo e pode afetar a previsibilidade clínica de cada etapa. Evidencia-se que a termoformagem e a espessura efetiva do alinhador modificam propriedades finais do dispositivo, contribuindo para variabilidade entre materiais e dificultando comparações quando há heterogeneidade metodológica. Analisa-se, ainda, o impacto do envelhecimento em meio bucal simulado, incluindo absorção de água, variações térmicas, alterações de rugosidade e mudanças ópticas, com potenciais repercussões estéticas e de higiene. Quanto à segurança biológica, discutem-se ensaios de biocompatibilidade e investigações sobre liberação de compostos, com necessidade de interpretação cautelosa diante de diferenças de protocolo. Conclui-se que não há superioridade universal de um único polímero, e reforça-se a importância de padronização de métodos e de estudos que integrem caracterização de materiais e desfechos clínicos. |
pt_BR |
| dc.description.abstract |
This study analyzes, through a narrative literature review, the polymers used in the
manufacture of orthodontic clear aligners and the relationship between their properties
and the clinical performance of these devices. A bibliographic search was conducted
in PubMed, PubMed Central (PMC), SciELO, and LILACS throughout 2025, prioritizing
studies published within the last five years and exceptionally including seminal studies
for conceptual grounding. The synthesis was organized into thematic axes addressing
the main classes of thermoplastics used in aligners, with emphasis on PETG-based
materials, thermoplastic polyurethanes, copolymers, polymer blends, and multilayer
architectures, as well as processing-related aspects. The viscoelastic behavior of
polymers, expressed by stress relaxation and creep, is discussed as a key factor
governing time-dependent force decay and potentially affecting the predictability of
planned tooth movements, especially when variations in thickness, coverage, and fit
are considered. Thermoforming is highlighted as a critical step that alters
microstructure, thickness distribution, and surface properties, thereby modifying
stiffness, elastic recovery, and dimensional stability and contributing to heterogeneity
across brands and methodological limitations among studies. The impact of aging
under simulated oral conditions is also addressed, including water sorption, thermal
variations, changes in surface roughness, staining, and optical changes, with potential
consequences for esthetics, hygiene, and patient adherence. From a biological
standpoint, evidence regarding biocompatibility, in vitro cytotoxicity, biofilm formation,
and the potential release of chemical compounds is examined, emphasizing the need
for cautious interpretation based on the tested material, extraction medium, and
analytical method. It is concluded that no single polymer is universally superior and
that clinical decisions should consider force maintenance, dimensional stability, and
surface behavior, supporting methodological standardization and studies integrating
material characterization with clinical outcomes. |
pt_BR |
| dc.format.extent |
54f |
pt_BR |
| dc.language.iso |
por |
pt_BR |
| dc.publisher |
Florianópolis, SC. |
pt_BR |
| dc.rights |
Open Access. |
en |
| dc.subject |
alinhadores ortodônticos |
pt_BR |
| dc.subject |
polímeros |
pt_BR |
| dc.subject |
materiais termoplásticos |
pt_BR |
| dc.subject |
termoformagem |
pt_BR |
| dc.subject |
propriedades mecânicas |
pt_BR |
| dc.title |
Análise de polímeros utilizados na fabricação de alinhadores odontológicos: revisão de literatura |
pt_BR |
| dc.type |
TCCgrad |
pt_BR |