dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina. Campus Joinville. Engenharia Aeroespacial. |
pt_BR |
dc.description.abstract |
Este trabalho consiste em um estudo sobre a viabilidade no uso da termografia infravermelha
na detecção de defeitos internos em materiais compósitos, especificamente, fibra de carbono.
Defeitos podem ocorrer durante a fabricação ou a operação de componentes a base de fibra de
carbono defeitos que muitas vezes são internos ou invisíveis a olho nu e podem causar uma
falha catastrófica do componente. Por isso, um método de detecção de defeitos é de extrema
importância. Para este estudo foram confeccionadas três amostras de fibra de carbono, duas
contendo defeitos internos do tipo vazio, criados por um espaço vazio entre as camadas de fibra,
e uma amostra de controle sem defeito. Posteriormente essas amostras foram analisadas usando
termografia infravermelha. As amostras foram aquecidas em um banho de água quente, e então
fotografadas por uma câmera infravermelha, nas temperaturas de 50ºC, 40ºC e 30ºC, para que
o defeito pudesse ser encontrado a partir da imagem infravermelha. No geral os resultados fo-
ram condizentes com a teoria, sendo possível encontrar o defeito de no mínimo 30mm mesmo
com a amostra a 30ºC, o que represente uma variação de menos de 5ºC para com a temperatura
ambiente. |
pt_BR |
dc.description.abstract |
This work consists on a study about the viability of the usage of infrared thermography on the
detection of internal defects on composite materials, specially, carbon fiber. Defects can occur
during the fabrication prosses or during the operation of carbon fiber components this defects
usually are in the interior or invisible at naked eye and can cause a catastrophic failure of the
component. Because of that, a defect detection method is so important. For this work, tree car-
bon fiber samples containing a defect were made, two containing defects created by a void in
the middle of the carbon fiber layers, and a control sample without defect. Later this samples
were analyzed using infrared thermography. The samples were heated using a hot water bath,
and then photographed using an infrared camera, at 50ºC, 40ºC and 30ºC, that way the infrared
image could be used to find the defect. In general, the results were in line with the theory, being
possible to find at minimum a 30mm defect even with the sample at 30ºC, which represents less
than 5ºC of difference with the ambient temperature. |
pt_BR |
dc.format.extent |
50 f |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Joinville, SC |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Fibra |
pt_BR |
dc.subject |
Carbono |
pt_BR |
dc.subject |
Termografia |
pt_BR |
dc.subject |
Infravermelho |
pt_BR |
dc.title |
Termografia aplicada na detecção de defeitos em compósitos de fibra de carbono e resina epóxi |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar