dc.description |
TCC(graduação) - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Medicina. |
pt_BR |
dc.description.abstract |
Os pacientes submetidos ao Reparo Endovascular de Aneurisma (Endovascular Aneurysm
Repair, EVAR) precisam manter um acompanhamento com exames de imagem a longo
prazo. O Ecodoppler associado ao contraste de microbolhas (CMB) vem sendo utilizado e
estudado como método alternativo a angiotomografia (angioTC) no acompanhamento desses
pacientes. Objetivos: descrever os resultados iniciais do Ecodoppler, com e sem o CMB, no
acompanhamento de pacientes submetidos ao EVAR. Bem como, nos casos possíveis, fazer
uma sumária comparação desses achados com os apresentados pela angioTC. Métodos:
análise retrospectiva dos exames de Ecodoppler com CMB e angioTC de 95 pacientes
submetidos ao EVAR em clínica privada, de outubro de 2019 a março de 2021. Para fins
comparativos, considerou-se exames de CMB e angioTC com diferença menor que 6 meses
entre si. Resultados: nessa amostra, 93,7% dos pacientes são do sexo masculino e 12,6%
apresentavam outros tipos de aneurismas associados. O volume médio de CMB utilizado foi
de 2,25 ml por paciente, não havendo qualquer reação ou intercorrência. A medida do
diâmetro da dilatação aórtica residual não apresentou diferença significativa entre os achados
de angioTC e Ecodoppler. Ao Ecodoppler com e sem CMB, foram observadas 7 estenoses
significativas, enquanto que 2 foram apontadas pela angioTC. Um único caso de oclusão da
endoprótese foi identificado por ambos os exames. Na análise individualizada dos exames de
imagem, foram detectados 11 endoleaks ao Ecodoppler sem CMB, 37 após a injeção do
CMB e 16 pela angioTC. Na análise específica do grupo comparativo entre CMB e angioTC,
foram detectados 9 endoleaks tanto pela angioTC quanto pelo Ecodoppler com CMB, 1
endoleak foi detectado apenas pela angioTC e 5 endoleaks detectados somente após a injeção
do contraste de microbolhas. Considerando o CMB como padrão de referência, observou-se
uma sensibilidade do CMB 26,67% maior que o da angioTC na detecção de endoleaks.
Conclusão: o Ecodoppler associado ao CMB é uma alternativa viável no acompanhamento
de pacientes submetidos ao EVAR por apresentar menor custo, não utilizar radiação ionizante
ou contraste iodado, além de possuir, na respectiva amostra, sensibilidade e especificidade
superior à da angioTC na detecção de endoleaks. |
pt_BR |
dc.description.abstract |
Patients undergoing Endovascular Aneurysm Repair (EVAR) need to maintain long-term
follow-up imaging. Contrast-Enhanced Ultrasound (CEUS) has been used and studied as an
alternative method to computed tomography angiography (CT angiography) in the follow-up
of these patients. Objectives: to describe the initial results of the experience with the use of
CEUS, in the follow-up of patients undergoing EVAR. As well as, in the possible cases, to
make a summarized comparison of these findings with those presented by CTA. Methods:
retrospective analysis of CEUS’s results of 95 patients who underwent EVAR in a private
clinic, from October 2019 to March 2021. For comparative purposes, it was considered
CEUS and CTA exams with a difference of less than 6 months. Results: in this sample,
93.7% of the patients were male and 12.6% had other types of associated aneurysms. The
average volume of CEUS used was 2.25 ml per patient, with no reaction or intercurrence.
The measurement of the diameter of residual aortic dilatation showed no significant
difference between the CTA and Doppler echo findings. At CEUS, 7 significant stenosis were
observed while 2 were identified by CT angiography. A single case of endoprosthesis
occlusion was identified by both exams. In the individual analysis of the imaging exams, 11
endoleaks were detected by Echo-Doppler, 37 after CEUS and 16 by CTA. In the specific
analysis of the comparison group between CEUS and CTA, 9 endoleaks were detected both
by CT angiography and by CEUS, 1 endoleak detected only by CTA and 5 endoleaks
detected only after injection of the ultrasound contrast. Considering CEUS as a reference
standard, CEUS sensitivity is 26.67% higher than that of CTA in the detection of endoleaks.
Conclusion: CEUS may be a viable alternative in the follow-up of patients undergoing
EVAR because it has a lower cost, does not use ionizing radiation or iodinated contrast, in
addition to having, in this sample, sensitivity and superior specificity to that of CT
angiography in the detection of endoleaks. |
pt_BR |
dc.format.extent |
43 |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Correção endovascular de aneurisma de aorta |
pt_BR |
dc.subject |
EVAR |
pt_BR |
dc.subject |
Endoleak |
pt_BR |
dc.subject |
Ultrassonografia com contraste de microbolhas |
pt_BR |