Dispositivo para estimar o volume infundido em terapia intravenosa

DSpace Repository

A- A A+

Dispositivo para estimar o volume infundido em terapia intravenosa

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Marques, Jefferson Luiz Brum
dc.contributor.author Milioli, Duane José
dc.date.accessioned 2019-12-09T13:27:13Z
dc.date.available 2019-12-09T13:27:13Z
dc.date.issued 2019-11-27
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/202535
dc.description TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Eletrônica. pt_BR
dc.description.abstract O dispositivo foi desenvolvido para estimar a vazão de um fluido utilizado em terapia de infusão intravenosa pelo método gravitacional. Ele utiliza como sensor um fototransistor que usa o método de interrupção da radiação infravermelha pela passagem das gotas na câmara de gotejamento de um equipo. O volume total do fluido no frasco é previamente selecionado e durante a passagem das gotas pode ser verificado visualmente o volume restante e a vazão. O valor do volume restante é transmitido por Bluetooth® até um outro módulo que recebe os dados, os processa e os envia por rede de internet para disponibilidade em um servidor. Os dados podem ser verificados em uma central, inclusive com alarmes para informar sobre a proximidade do final da terapia. O sistema proposto tende a facilitar a rotina diária de um hospital, diminuindo o trabalho dos profissionais e deslocando sua atenção para focos mais importantes no diagnóstico e terapêutica. O dispositivo pode ter seu algoritmo modificado para atender outras necessidades da área da saúde. pt_BR
dc.description.abstract The device was developed to estimate the flow of a fluid used in intravenous infusion therapy by the gravitational method. It uses as a sensor a phototransistor that uses the method of interrupting infrared radiation by the passage of drops in a drip chamber of a device. The total volume of fluid in the vial is pre-selected and during droplet passage the remaining volume and flow rate can be visually checked. The remaining volume value is transmitted via Bluetooth® to another module that receives the data, processes it and sends it over the internet for availability on a server. Data can be checked at a switch, including alarms to inform you about the end of therapy. The proposed system tends to facilitate the daily routine of a hospital, reducing the work of professionals and shifting their attention to more important focuses on diagnosis and therapy. The device may have its algorithm modified to meet other healthcare needs. pt_BR
dc.format.extent 78 pt_BR
dc.language.iso por pt_BR
dc.publisher Florianópolis, SC pt_BR
dc.rights Open Access
dc.subject Terapia intravenosa pt_BR
dc.subject Vazão pt_BR
dc.subject Contador pt_BR
dc.subject Gotas pt_BR
dc.subject Bluetooth pt_BR
dc.title Dispositivo para estimar o volume infundido em terapia intravenosa pt_BR
dc.type TCCgrad pt_BR


Files in this item

Files Size Format View Description
DuaneJoseMilioli.pdf 35.75Mb PDF View/Open TCC