Dispositivo para estimar o volume infundido em terapia intravenosa
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Marques, Jefferson Luiz Brum |
|
dc.contributor.author |
Milioli, Duane José |
|
dc.date.accessioned |
2019-12-09T13:27:13Z |
|
dc.date.available |
2019-12-09T13:27:13Z |
|
dc.date.issued |
2019-11-27 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/202535 |
|
dc.description |
TCC(graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Eletrônica. |
pt_BR |
dc.description.abstract |
O dispositivo foi desenvolvido para estimar a vazão de um fluido utilizado em terapia de infusão intravenosa pelo método gravitacional. Ele utiliza como sensor um fototransistor que usa o método de interrupção da radiação infravermelha pela passagem das gotas na câmara de gotejamento de um equipo. O volume total do fluido no frasco é previamente selecionado e durante a passagem das gotas pode ser verificado visualmente o volume restante e a vazão. O valor do volume restante é transmitido por Bluetooth® até um outro módulo que recebe os dados, os processa e os envia por rede de internet para disponibilidade em um servidor. Os dados podem ser verificados em uma central, inclusive com alarmes para informar sobre a proximidade do final da terapia. O sistema proposto tende a facilitar a rotina diária de um hospital, diminuindo o trabalho dos profissionais e deslocando sua atenção para focos mais importantes no diagnóstico e terapêutica. O dispositivo pode ter seu algoritmo modificado para atender outras necessidades da área da saúde. |
pt_BR |
dc.description.abstract |
The device was developed to estimate the flow of a fluid used in intravenous infusion therapy by the gravitational method. It uses as a sensor a phototransistor that uses the method of interrupting infrared radiation by the passage of drops in a drip chamber of a device. The total volume of fluid in the vial is pre-selected and during droplet passage the remaining volume and flow rate can be visually checked. The remaining volume value is transmitted via Bluetooth® to another module that receives the data, processes it and sends it over the internet for availability on a server. Data can be checked at a switch, including alarms to inform you about the end of therapy. The proposed system tends to facilitate the daily routine of a hospital, reducing the work of professionals and shifting their attention to more important focuses on diagnosis and therapy. The device may have its algorithm modified to meet other healthcare needs. |
pt_BR |
dc.format.extent |
78 |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.publisher |
Florianópolis, SC |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
Terapia intravenosa |
pt_BR |
dc.subject |
Vazão |
pt_BR |
dc.subject |
Contador |
pt_BR |
dc.subject |
Gotas |
pt_BR |
dc.subject |
Bluetooth |
pt_BR |
dc.title |
Dispositivo para estimar o volume infundido em terapia intravenosa |
pt_BR |
dc.type |
TCCgrad |
pt_BR |
Files in this item
This item appears in the following Collection(s)