Classificação Energética de Salas Comerciais e Alternativa para Obtenção de Consumo Energético Nulo Estudos de Caso: Cafeteria e Escritório Localizados em Florianópolis

DSpace Repository

A- A A+

Classificação Energética de Salas Comerciais e Alternativa para Obtenção de Consumo Energético Nulo Estudos de Caso: Cafeteria e Escritório Localizados em Florianópolis

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Fossati, Michele
dc.contributor.author Costenaro, Arthur Voos
dc.date.accessioned 2019-07-15T14:56:28Z
dc.date.available 2019-07-15T14:56:28Z
dc.date.issued 2019-06-28
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/197581
dc.description TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Civil. pt_BR
dc.description.abstract Este trabalho tem como objetivo a classificação da eficiência energética de um escritório e uma cafeteria localizados em Florianópolis – SC, além da possibilidade de torná-los edificações de balanço energético nulo. Para o cálculo do consumo de energia elétrica e avaliação dos sistemas foi utilizado o método simplificado apresentado na Instrução Normativa Inmetro para a Classe de Eficiência Energética de Edificações Comercias, de Serviços e Públicas - INI-C. A partir da metodologia apresentada e considerando tanto a condição real quanto a condição de referência das edificações, foi possível avaliar as envoltórias, os sistemas de condicionamento de ar e os sistemas de iluminação quanto a sua eficiência energética. Foi também realizada a avaliação geral das salas de acordo com o seu consumo convertido em energia primária. Ambos obtiveram classificação geral B. Discutiu-se algumas alternativas para tentar mudar de forma positiva o cenário encontrado. Por fim, foram dimensionados sistemas de energia fotovoltaica para suprir integralmente os consumos energéticos das salas, tornando-as de energia zero. pt_BR
dc.description.abstract cis works aim is to classify the energy efficiency of an office and a cafeteria located in Florianópolis - SC, besides the possibility of making them buildings with zero energy balance. ce simplified method presented in the Inmetro Normative Instruction for the Energy Efficiency Class of Commercial, Services and Public Buildings (INI-C) was used to calculate electricity consumption and to classify the systems. Based on the methodology presented and considering both the actual condition and the reference condition of the buildings, it was possible to evaluate the envelopes, the air conditioning systems and the lighting systems regarding their energy efficiency. ce general classification of the rooms was also carried out according to their energy consumption converted into primary energy. Both obtained general classification B. Some alternatives were discussed in order to change the found scenario in a positive way. Finally, photovoltaic energy systems were dimensioned to fully meet the energy consumption of the rooms, making them zero energy. pt_BR
dc.format.extent 91 pt_BR
dc.language.iso por pt_BR
dc.publisher Florianópolis, SC pt_BR
dc.rights Open Access
dc.subject Eficiência Energética pt_BR
dc.subject INI-C pt_BR
dc.subject Edifícios de Energia Zero pt_BR
dc.title Classificação Energética de Salas Comerciais e Alternativa para Obtenção de Consumo Energético Nulo Estudos de Caso: Cafeteria e Escritório Localizados em Florianópolis pt_BR
dc.type TCCgrad pt_BR


Files in this item

Files Size Format View
TCC_Arthur_Costenaro.pdf 8.765Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar