Análise térmica e hidrodinâmica de um trocador de placas brazado - PHE

Repositório institucional da UFSC

A- A A+

Análise térmica e hidrodinâmica de um trocador de placas brazado - PHE

Mostrar registro simples

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Vieira de Paiva, Kleber
dc.contributor.author Grüttner, Gesiel
dc.date.accessioned 2019-07-10T10:48:02Z
dc.date.available 2019-07-10T10:48:02Z
dc.date.issued 2019-06-26
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/197301
dc.description TCC (graduação) - Universidade Federal de Santa Catarina. Campus Joinville. Engenharia Aeroespacial. pt_BR
dc.description.abstract Trocadores de calor a placas têm sido utilizados para transferência de calor desde o início do século passado. Devido ao grande leque de configurações possíveis, o desenvolvimento de um modelo analítico único não é possível. Uma possibilidade de minimizar essas incertezas é o desenvolvimento de modelos térmicos e hidrodinâmicos específicos. Validar modelos propostos na literatura usando dados experimentais foi o objetivo principal deste trabalho. Os resultados obtidos apontam uma boa convergência entre os dados experimentais obtidos e os modelos monofásicos. Para a transferência de calor, usando a correlação de Muley (1999), obteve-se um erro máximo de 9% para o ramal água e 4% para o ramal ar. Para a perda de carga, a correlação de Savostin e Tikhonov (1971) foi a que mais se aproximou dos resultados experimentais, com um erro máximo de 25% na fase ar. pt_BR
dc.description.abstract Plate heat exchangers have been used for heat transfer since the beginning of the last century. Due to the wide range of possible configurations, the development of a unique analytical model is not possible. One possibility to minimize these uncertainties is the development of reliable and specific thermal and hydrodynamic models. Validating models proposed in the literature using experimental data was the main objective of this work. The results obtained indicate a good convergence between the experimental data and the single-phase models. For the heat transfer, using the Muley correlation (1999), a maximum error of 9% was obtained for the water branch and 4% for the branch air. For the pressure loss, the correlation of Savostin and Tikhonov (1971) was the one that most approached the experimental data, with a maximum error of 25% in the air branch. pt_BR
dc.format.extent 59 pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Joinville, SC pt_BR
dc.rights Open Access
dc.subject PHE pt_BR
dc.subject Transferência de calor pt_BR
dc.subject Perda de carga pt_BR
dc.subject Nusselt pt_BR
dc.title Análise térmica e hidrodinâmica de um trocador de placas brazado - PHE pt_BR
dc.type TCCgrad pt_BR


Arquivos deste item

Arquivos Tamanho Formato Visualização
TCC - Gesiel - Final.pdf 2.426Mb PDF Visualizar/Abrir

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Navegar

Minha conta

Estatística

Compartilhar