Análise térmica e hidrodinâmica de um trocador de placas brazado - PHE
Mostrar registro simples
dc.contributor |
Universidade Federal de Santa Catarina |
pt_BR |
dc.contributor.advisor |
Vieira de Paiva, Kleber |
|
dc.contributor.author |
Grüttner, Gesiel |
|
dc.date.accessioned |
2019-07-10T10:48:02Z |
|
dc.date.available |
2019-07-10T10:48:02Z |
|
dc.date.issued |
2019-06-26 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/197301 |
|
dc.description |
TCC (graduação) - Universidade Federal de Santa Catarina. Campus Joinville. Engenharia Aeroespacial. |
pt_BR |
dc.description.abstract |
Trocadores de calor a placas têm sido utilizados para transferência de calor desde o início do século passado. Devido ao grande leque de configurações possíveis, o desenvolvimento de um modelo analítico único não é possível. Uma possibilidade de minimizar essas incertezas é o desenvolvimento de modelos térmicos e hidrodinâmicos específicos. Validar modelos propostos na literatura usando dados experimentais foi o objetivo principal deste trabalho. Os resultados obtidos apontam uma boa convergência entre os dados experimentais obtidos e os modelos monofásicos. Para a transferência de calor, usando a correlação de Muley (1999), obteve-se um erro máximo de 9% para o ramal água e 4% para o ramal ar. Para a perda de carga, a correlação de Savostin e Tikhonov (1971) foi a que mais se aproximou dos resultados experimentais, com um erro máximo de 25% na fase ar. |
pt_BR |
dc.description.abstract |
Plate heat exchangers have been used for heat transfer since the beginning of the last century. Due to the wide range of possible configurations, the development of a unique analytical model is not possible. One possibility to minimize these uncertainties is the development of reliable and specific thermal and hydrodynamic models. Validating models proposed in the literature using experimental data was the main objective of this work. The results obtained indicate a good convergence between the experimental data and the single-phase models. For the heat transfer, using the Muley correlation (1999), a maximum error of 9% was obtained for the water branch and 4% for the branch air. For the pressure loss, the correlation of Savostin and Tikhonov (1971) was the one that most approached the experimental data, with a maximum error of 25% in the air branch. |
pt_BR |
dc.format.extent |
59 |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Joinville, SC |
pt_BR |
dc.rights |
Open Access |
|
dc.subject |
PHE |
pt_BR |
dc.subject |
Transferência de calor |
pt_BR |
dc.subject |
Perda de carga |
pt_BR |
dc.subject |
Nusselt |
pt_BR |
dc.title |
Análise térmica e hidrodinâmica de um trocador de placas brazado - PHE |
pt_BR |
dc.type |
TCCgrad |
pt_BR |