Análise das incertezas na identificação dos caminhos de propagação da energia vibratória em refrigeradores domésticos usando o método Transfer Path Analysis
Show simple item record
dc.contributor |
Universidade Federal de Santa Catarina |
|
dc.contributor.advisor |
Lenzi, Arcanjo |
|
dc.contributor.author |
Silva, Guilherme Henrique da |
|
dc.date.accessioned |
2018-09-20T04:04:43Z |
|
dc.date.available |
2018-09-20T04:04:43Z |
|
dc.date.issued |
2018 |
|
dc.identifier.other |
355398 |
|
dc.identifier.uri |
https://repositorio.ufsc.br/handle/123456789/190064 |
|
dc.description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2018. |
|
dc.description.abstract |
A análise do fluxo de energia vibratória de um compressor para o gabinete do sistema de refrigeração foi realizada usando o procedimento Transfer Path Analysis (TPA). Para isso, foi utilizado o Método das Forças Equi- valentes (MFE) e funções recíprocas de resposta em frequência do compo- nente que suporta o compressor e a pressão sonora radiada pelo gabinete. Dois procedimentos diferentes foram utilizados para a caracterização da fonte de velocidade de volume com a qual vibrações foram excitadas no gabinete e funções de resposta em frequência obtidas. Uma análise das principais fontes de incertezas relacionadas aos vários caminhos de pro- pagação da energia vibratória foi também realizada a fim de identificar os cuidados necessários à aplicação desta metodologia. Foram obtidos re- sultados com margens de até 95% de confiança e as respectivas fontes de incertezas identificadas e discutidas. |
|
dc.description.abstract |
Abstract : An analysis of the vibratory energy flux of a compressor to the cabinet of a refrigeration system was done using the transfer path analysis procedure. The procedure used the equivalent forces method (EFM) and reciprocal frequency response functions of the compressor s supporting component and the sound pressure radiated by the cabinet. Two different procedures were used for volume velocity sources characterization, which then were used to excite vibrations on the cabinet and obtain frequency response functions. An analysis of the main sources of uncertainties related to the several paths of vibratory energy propagation was also made, with the object to identify the necessary precautions to the application of this methodology. Results were obtained with up to 95% confidence and the respective uncertainty sources are identified and discussed. |
en |
dc.format.extent |
91 p.| il., gráfs. |
|
dc.language.iso |
por |
|
dc.subject.classification |
Engenharia mecânica |
|
dc.subject.classification |
Refrigeradores |
|
dc.title |
Análise das incertezas na identificação dos caminhos de propagação da energia vibratória em refrigeradores domésticos usando o método Transfer Path Analysis |
|
dc.type |
Dissertação (Mestrado) |
|
Files in this item
This item appears in the following Collection(s)
Show simple item record
Search DSpace
Browse
-
All of DSpace
-
This Collection
My Account
Statistics
Compartilhar