Análise pelo método dos elementos finitos da distribuição de tensões em tecido ósseo periimplantar, componentes protéticos e implantes com conexão cono morse e hexágono externo reabilitados com diferentes desenhos protéticos na região anterior da maxila

DSpace Repository

A- A A+

Análise pelo método dos elementos finitos da distribuição de tensões em tecido ósseo periimplantar, componentes protéticos e implantes com conexão cono morse e hexágono externo reabilitados com diferentes desenhos protéticos na região anterior da maxila

Show simple item record

dc.contributor Universidade Federal de Santa Catarina pt_BR
dc.contributor.advisor Cardoso, Antonio Carlos pt_BR
dc.contributor.author Villabona Lopez, Camilo Andres pt_BR
dc.date.accessioned 2017-10-24T03:18:34Z
dc.date.available 2017-10-24T03:18:34Z
dc.date.issued 2017 pt_BR
dc.identifier.other 347973 pt_BR
dc.identifier.uri https://repositorio.ufsc.br/xmlui/handle/123456789/180423
dc.description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. pt_BR
dc.description.abstract O objetivo desse estudo foi analisar pelo método dos elementos finitos a distribuição e picos de tensão em prótese parcial fixa (12-22) e prótese parcial fixa com cantiléver distal bilateral (11-21) suportadas por implantes de hexágono externo e cone morse na região anterior da maxila. As duas situações clínicas foram simuladas em terceira dimensão, analisadas e comparadas qualitativamente segundo o mapa de cores e quantitativamente por meio dos Critérios de Rankine para infraestrutura e cerâmica, o Critério equivalente Von Mises para os implantes, pilares e parafusos passantes e o Critério Mohr Coulomb para o tecido ósseo periimplantar. O teste foi realizado com aplicações de carga de 400 N com angulação de 45º em relação ao longo eixo da prótese. Foi observado que as tensões na cerâmica diminuíram 103% e 110% para próteses sem cantiléver sendo o pico de maior tensão na região da extensão distal. Independentemente do tipo de desenho protético os pilares cone morse diminuíram 38% dos picos de tensão em relação ao hexágono externo. Em contrapartida a conexão hexágono externo reduziu os valores dos picos de tensão em 20% na região ossea periimplantar em relação à conexão cone morse. De acordo com as limitações deste estudo, evindenciou-se que independentemente da conexão protética, a prótese parcial fixa com cantiléver distal bilateral aumentou os picos de tensão na cerâmica. Independentemente do tipo de desenho protético, a conexão cone morse aumentou os picos de tensão no osso periimplantar e o hexágono externo no pilar. A plotagem gráfica da distribuição de tensões evidenciou que os picos de tensão na infraestrutura, parafuso protético e implante foram similares entre os grupos analisados.<br> pt_BR
dc.description.abstract Abstract : The aim of the present study was to analyze the mechanics of the distribution and stress peaks in fixed partial prostheses (12-22) and fixed partial protheses with a bilateral distal cantilever (11-21) supported by external hexagon and morse taper in the anterior region of the maxilla. The two clinical situations were simulated in three dimension, analyzed and compared qualitatively according to the color map and quantitatively using the Rankine criteria for the infrastructure and ceramics, the Von Mises equivalent criterion for implants, abutments and screws and the Mohr Coulomb criterion for the peri-implant bone tissue. The test was performed with load applications of 400 N with an angle of 45º in relation to the long axis of the prosthesis. It was observed that the ceramic stress decreased 103% and 110% for the non-cantilevered prostheses with the peak of greater stress in the distal exstress region. Regardless of the type of prosthetic design, the morse taper abutments decreased 38% of the stress peaks in relation to the external hexagon, and external hexagon reduced the values of the stress peaks 20% in the peri-implantar osseous region in relation to the cone morse connection. According to the limitations of the present study, it was shown that, independently of the prosthetic connection, the fixed partial prosthesis with a bilateral distal cantilever increased the stress peaks in the ceramics. Regardless of the type of prosthetic design, the cone morse connection increased the stress peaks in the peri-implantar bone and the external hexagon in the abutment. The graphical plot of the stress distribution showed that the stress peaks in the infrastructure, prosthetic screw and implant were similar between the analyzed groups. en
dc.format.extent 135 p.| il., gráfs., tabs. pt_BR
dc.language.iso por pt_BR
dc.subject.classification Odontologia pt_BR
dc.subject.classification Método dos elementos finitos pt_BR
dc.subject.classification Engenharia biomédica pt_BR
dc.subject.classification Implantes dentários pt_BR
dc.subject.classification Prótese dentária pt_BR
dc.title Análise pelo método dos elementos finitos da distribuição de tensões em tecido ósseo periimplantar, componentes protéticos e implantes com conexão cono morse e hexágono externo reabilitados com diferentes desenhos protéticos na região anterior da maxila pt_BR
dc.type Tese (Doutorado) pt_BR
dc.contributor.advisor-co Vasco, Marco Antônio Amorim pt_BR


Files in this item

Files Size Format View
347973.pdf 3.288Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar