A influência da temperatura de armazenamento na microdureza de uma resina composta

DSpace Repository

A- A A+

A influência da temperatura de armazenamento na microdureza de uma resina composta

Show simple item record

dc.contributor Universidade Federal de Santa Catarina en
dc.contributor.advisor Prates, Luiz Henrique Maykot
dc.contributor.author Benincá, Alexandre Pizzetti
dc.date.accessioned 2013-11-25T00:52:08Z
dc.date.available 2013-11-25T00:52:08Z
dc.date.issued 2013-10-31
dc.date.submitted 2013-10-31
dc.identifier.uri https://repositorio.ufsc.br/handle/123456789/105867
dc.description TCC (graduação) - Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Odontologia. en
dc.description.abstract O objetivo deste estudo foi de comparar a microdureza de uma resina composta acondicionada em temperatura ambiente (~21ºC) com outra armazenada em um refrigerador (~3ºC). Para tanto, 9 bisnagas de resina Opallis A2 (FGM, Joinville, SC, Brasil) foram divididas em três grupos e acondicionadas por 5 meses em diferentes temperaturas: GA (n=10), à temperatura ambiente; GB(n=10), em ambiente refrigerado, mas com espera de uma hora fora da geladeira para fotoativação; e GC(n=10), com resinas resfriadas durante todo o tempo, até mesmo durante a fotoativação. Metade das amostras de cada grupo foi testada logo após a polimerização e o restante com espera de uma semana. Todos os corpos de prova foram previamente lixados e polidos, para somente então serem submetidos ao teste. Os resultados mostraram melhores valores médios de microdureza imediata no GB (63,89), e após uma semana no GA (73,66). As médias de todos os grupos aumentaram após o tempo de espera. en
dc.description.abstract The aim of this study was to compare the Vicker Hardness of a composite stored at room temperature (~21ºC) with another stored at a lower temperature (3ºC). Nine Opallis A2 syringes (FGM, Joinville, SC, Brasil) were divided in 3 groups and stored for 5 months at different temperatures: GA (n=10), stored at room temperature; GB (n=10), stored in a cold environment and light cured after 1 hour out at the room temperature; and GC (n=10), stored and light cured at a lower temperature. Half of the samples from each group were tested right after the light curing process, and the other half was tested after one week. All the samples were previously polished in order to be submitted to the hardness test. The results demonstrated a better immediate hardness medium values on the GB (63,89), and one week later at GA (73,66). All the group’s medium values had risen after the waiting time. en
dc.format.extent 25 f. en
dc.language.iso por en
dc.subject resina composta en
dc.subject armazenamento en
dc.subject refrigeração en
dc.subject temperatura en
dc.subject microdureza en
dc.title A influência da temperatura de armazenamento na microdureza de uma resina composta en
dc.type TCCgrad en


Files in this item

Files Size Format View
TCC FINAL.pdf 745.4Kb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics

Compartilhar